At a Warsaw lab, a camera watched tiny bright and dark specks in returning laser light shift as blood cells moved beneath the skin. Those changes can reveal blood flow, but at the forehead the signal mixes circulation in the scalp with signals from deeper tissue. That makes it hard to tell what an optical reading says about blood supply farther below the surface.
Researchers associated with the International Centre for Translational Eye Research (ICTER) in Warsaw have combined two light-measuring methods in a system called hybrid interferometric near-infrared spectroscopy, or hybrid iNIRS. Their demonstration, published in Scientific Reports, suggests that the system can preserve information about blood flow while sorting returning light by how long it took to travel through tissue. The approach could help researchers study circulation at different depths without making an incision.
The team included Marcin Marzejon, who previously worked at ICTER and the Institute of Physical Chemistry of the Polish Academy of Sciences, and Dawid Borycki, leader of ICTER’s PICO group. Their setup used a laser with a wavelength of about 780 nanometers, in the near-infrared range. Light scatters many times as it travels through tissue. When it emerges, it forms a speckled pattern. Red blood cells in motion cause that pattern to change, and the speed of those changes can be used to calculate a blood-flow index—a measure of how circulation is changing.
The second part of the method uses the light’s time of flight: how long photons, or packets of light, take to reach the detector. Later-arriving photons have generally traveled longer paths and carry a greater contribution from deeper tissue. They do not come only from deep tissue, since their routes can still pass through both shallow and deeper areas. But separating photons by arrival time can shift how much each depth contributes to the measurement.
Conventional iNIRS can distinguish light by time of flight, but it collects relatively few photons. Camera-based methods gather many more, yet rapid changes in living tissue make it difficult to use them to separate signals by arrival time. The hybrid system combines the two approaches. In tests on two healthy volunteers, the researchers measured the forearm and forehead. On the forearm, they recorded blood flow before a cuff blocked circulation, during the blockage, and after its release. The light-signal changes slowed during the blockage, then showed a temporary rise above the starting level after blood flow returned.
At the forehead, a headband was tightened to restrict circulation in the scalp. The response in later-arriving light was weaker, a result consistent with that signal containing a greater contribution from deeper tissue. The test offers an early demonstration, not a direct measurement of brain blood flow or a clinical diagnosis. Still, it shows how combining photon timing with camera-based blood-cell motion signals may help researchers separate surface circulation from deeper signals. Further work will be needed to establish how reliably the method can do so across people and settings.