A five-second test in Hefei can now detect hydrogen at just one part per million, a level that could help engineers spot small leaks in power equipment before they become harder to find. The system was developed by a team led by Professor Fang Yonghua at the Hefei Institutes of Physical Science of the Chinese Academy of Sciences.

Hydrogen monitoring matters in power equipment, energy systems and chemical plants, where even a small leak or change in gas levels can signal a problem. But hydrogen is difficult to measure: it absorbs infrared light only weakly, making tiny concentrations hard to distinguish from background signals. The researchers’ approach aims to make that faint signal clearer.

Their system uses photoacoustic stimulated Raman spectroscopy, or PA-SRS. This method turns light absorbed by a gas into sound that can be measured. In ordinary setups, unwanted signals from the measurement cell’s windows can get in the way. The Hefei team combined two ways to reduce that interference: one limits optical disturbances, and the other filters unwanted acoustic signals.

The device has two parallel resonant tubes and two microphones. By comparing what the microphones record, it can reinforce the sound linked to hydrogen while canceling much of the background noise. The researchers also arranged optical components to reduce stray signals caused by laser reflections inside the cell.

In tests, the new design produced a signal-to-background ratio about 180 times higher than a conventional differential H-type cell with uncoated windows. It directly detected hydrogen at one part per million in five seconds. The team estimated its detection limit at 0.25 parts per million, meaning the system may be able to identify concentrations below the level used in that direct test.

These results could support hydrogen leak monitoring and fault diagnosis in power equipment, where finding very low concentrations is important. The work does not establish that the system is already in routine use, but it shows how reducing interference can make a sensitive measurement more practical. Faster detection could give operators a clearer warning when equipment needs attention.

The findings were published in Sensors and Actuators B: Chemical. The team also published a review of spectroscopic methods for detecting hydrogen in Microwave and Optical Technology Letters. Further work will determine how the system performs in real operating environments, where reliable measurements can help turn a laboratory technique into a useful monitoring tool.