Meridia Insight Tech for Good Frontiers

A 1,452-state vibration model shrank to 834 without losing much accuracy

A vibration model lost 618 states and barely lost accuracy—showing how physical structure can make complex machine dynamics easier to use.

618 states removed; AVIS fit fell just 0.65 percentage points after physical modal reduction.

A model of an active vibration-isolation system began with 1,452 states. After MIMOS imposed a physically meaningful modal structure, it had 834—and its fit to measured frequency responses slipped from 94.10% to 93.45%. That small trade-off captures the point of this new open-source toolbox: turn sprawling measurements of complicated mechanical motion into models compact enough to understand and use.

The stakes are practical. High-performance machines—from precision wafer stages used in semiconductor manufacturing to vibration-isolated platforms—move through the world of flex, resonance and damping. Control systems must respond to those dynamics, but a controller is only as good as the model it is built on. A model that matches measurements but contains thousands of disconnected parameters can be hard to interpret, validate and use. A model with too much physical structure imposed too early can be difficult to fit accurately.

MIMOS, short for Multivariable Identification of Modal Optical and mechatronic Systems, is designed to bridge that gap. It takes measured frequency-response data from systems with many inputs and outputs, first fits the observed input-output behavior, then compresses that fit into a physical description in terms of modes—the characteristic ways a structure vibrates. In two experimental demonstrations, the approach preserved the measured behavior while reducing model order and parameter counts substantially (van der Hulst et al., 2026).

The Science

A mechanical system can be described, in simplified terms, by how its mass, stiffness and damping respond to applied forces. Push a structure at different frequencies and its response changes: some motions are amplified near resonance, while damping drains energy and limits the motion. Engineers summarize these dynamics using a frequency response function (FRF), which records how outputs such as position or velocity respond to inputs such as actuator forces across a range of frequencies.

When a system has several actuators and sensors, the result is a multivariable FRF: a matrix of responses, one for each input-output pairing. The systems in this paper are MIMO, or multiple-input, multiple-output. The prototype wafer stage, for example, has 17 actuator inputs and seven position measurements. Its measured behavior is not one curve but a linked collection of responses, shaped by many interacting vibration modes.

A modal model represents those responses through a set of modes, each with a characteristic natural frequency, damping and shape. Mode shapes describe how strongly different inputs excite a vibration and how strongly different outputs observe it. This physical structure is valuable: it lets an engineer reason about what the model represents, rather than treating it as a black box of unrelated coefficients.

But there is a catch. Each mode’s contribution across all input-output channels has a low-rank structure: it can be represented as combinations of input and output mode shapes. Estimating those factors directly creates a nonlinear problem, because parameters multiply one another. As the number of channels and modes rises, many parameters become coupled. A direct fit may be accurate, but computationally demanding and sensitive to how it is initialized.

MIMOS uses a two-stage strategy. In Stage 1, it fits an additive model to the measured FRFs. The model includes a separate mathematical contribution for each mode, but temporarily relaxes the physical factorization of each mode’s input-output effect. This lets the algorithm estimate the full measured behavior without immediately forcing every residue matrix into a physically constrained shape.

In Stage 2, the toolbox projects that flexible fit onto a physical modal model. The projection is information-weighted: it gives more influence to aspects of the Stage 1 estimate that are better determined by the data. In statistical terms, the weighting uses an estimate of the information matrix, which describes how strongly the measurements constrain different parameters. The result is not simply a generic simplification; it is a structured reduction intended to retain what the measurements actually support.

The workflow includes preprocessing and user choices as well as the core estimation. Users can select frequency ranges and channels, specify or estimate a common time delay, and choose weighting that emphasizes relative error, measurement variance or selected frequency bands. Candidate modes can be initialized automatically using a complex mode indicator function, then inspected and adjusted in an interactive workbench.

Figure 2: MIMOS workbench GUI for interactive modal initialization,
inspection of modal diagnostics, and reinitialization and restarting
of the identification procedure.
Figure 2: MIMOS workbench GUI for interactive modal initialization, inspection of modal diagnostics, and reinitialization and restarting of the identification procedure. Source: M. van der Hulst, R. A. González

One important option concerns damping. Proportional damping assumes a particularly tidy relationship: the same vibration shapes that diagonalize stiffness and mass also separate damping into independent modes. Real machines need not obey that simplification. MIMOS also supports general viscous damping, a broader representation that can capture more complex energy loss, at the cost of additional parameters.

What They Found

The first test was the Active Vibration Isolation System, or AVIS, a public benchmark with eight voice-coil actuators and six geophones. The researchers converted its measured velocity responses to displacement and identified 121 flexible modes from roughly 10,000 frequency points. The system is a useful stress test: six outputs and eight inputs create 48 response channels, while the many resonances make the model large.

With general viscous damping, Stage 1 estimated 11,906 parameters and achieved a reported FRF fit of 94.10%. The physical projection reduced the state-space model from 1,452 states to 834 and the independent parameter count from 11,906 to 7,892. The fit became 93.45%. That is a reduction of 618 states while retaining a fit above 93%—a concrete example of trading some flexibility for a more compact, physically interpretable representation.

The contrast with proportional damping was stark: using the same initialization, its reported fit was 67.35%. This does not prove that general damping is always the right choice. It does show that an overly restrictive physical assumption can become a major source of mismatch for a real system. The paper’s AVIS frequency-response plots compare measured data with the additive and modal fits; the close tracking after projection is visible across channels, including the highlighted output-6/input-8 response.

Figure 5: FRF magnitude plots for the 6×8 AVIS
benchmark showing estimated FRFs ()
with standard deviation (),
Stage 1 additive model (),
and Stage 2 modal model (),
with an enlarged view of channel Out. 6 / In. 8.
Figure 5: FRF magnitude plots for the 6×8 AVIS benchmark showing estimated FRFs () with standard deviation (), Stage 1 additive model (), and Stage 2 modal model (), with an enlarged view of channel Out. 6 / In. 8. Source: M. van der Hulst, R. A. González

AVIS: physical projection reduced model size with little fit loss

Reported Stage 1 and Stage 2 results for general viscous damping on the 6×8 AVIS benchmark. Separate measures are plotted as reported; state counts and fit percentages use their own units.

AVIS: physical projection reduced model size with little fit loss
LabelValue
Stage 1 states1,452 states
Stage 2 states834 states
Stage 1 fit94.1 states
Stage 2 fit93.45 states

The second demonstration was a prototype wafer stage, a precision positioning system relevant to semiconductor manufacturing. The stage has 17 actuator inputs and seven position measurements. MIMOS identified six rigid-body modes—motions such as translation or rotation without structural flexing—and 20 flexible modes from approximately 4,000 frequency points.

Here, the reduction was substantial and the fit changed very little. With proportional damping, Stage 2 reduced model order from 288 states to 84, while the fit moved from Stage 1 to 81.66%, a drop of 0.09 percentage points. With general viscous damping, the order fell from 288 to 90, and the Stage 2 fit was 82.85%, down 0.16 percentage points from Stage 1. The parameter count fell by 61.1% and 62.9%, respectively. Stage 2 took 3.4 seconds for proportional damping and 4.3 seconds for general damping, according to the paper.

Those results are not merely about smaller files. A compact model can be easier to inspect, share, compare with mechanical expectations and deploy in model-based control design. In a wafer stage, accurate control of motion is part of the chain that enables equipment to position materials precisely. Better system models can support controller design and diagnosis, though this paper tests identification—not a downstream manufacturing improvement.

Wafer stage: Stage 2 retains fit while reducing model order

Reported Stage 2 state-space order and FRF fit for the wafer-stage damping options.

Wafer stage: Stage 2 retains fit while reducing model order
LabelValue
Proportional damping order84 states
General damping order90 states
Proportional damping fit81.66 states
General damping fit82.85 states

MIMOS also selects how many physical components to retain within each mode. It uses singular values—numbers that indicate how much of a matrix’s contribution lies along different directions—to determine the rank needed to capture a user-selected share of the Stage 1 residue. The related singular vectors provide initial estimates for the input and output mode shapes. That provides a principled starting point for Stage 2’s nonlinear optimization, rather than asking the user to guess all the physical structure from scratch.

Figure 3: Normalized singular-value contributions of the Stage 1
modal residues used to select the number ri of physical
components per flexible mode.
Figure 3: Normalized singular-value contributions of the Stage 1 modal residues used to select the number ri of physical components per flexible mode. Source: M. van der Hulst, R. A. González

Wafer-stage independent parameter reduction

Stage 2 reduced the independent parameter count by the reported shares for each damping model.

Wafer-stage independent parameter reduction
LabelValue
Proportional damping61.1 %
General viscous damping62.9 %

The systems themselves make the broader point: modern mechatronics is often a coordination problem across many actuators and sensors.

Figure 4: Experimental systems used for validation:
AVIS benchmark (left) and prototype wafer stage (right).
Figure 4: Experimental systems used for validation: AVIS benchmark (left) and prototype wafer stage (right). Source: M. van der Hulst, R. A. González

As the number of channels grows, simplistic models may miss coupled motion, while unconstrained models can grow unwieldy. MIMOS’s result is an engineering compromise: keep a good account of the measured behavior, but express it in terms that retain a physical meaning.

Why This Changes Things

The central contribution is an integrated, open-source workflow rather than a new law of vibration. There are established methods for identifying modal behavior, and the two-stage approach itself had been developed in earlier work. The practical obstacle was that engineers lacked a single publicly available toolbox bringing together FRF preprocessing, initialization, estimation, diagnostics and refinement. MIMOS packages those steps in MATLAB, with example data and documentation available from the project repository cited in the paper.

That matters because software changes who can use a method. A theoretical method can remain difficult to reproduce if it requires bespoke code, specialist implementation or a long sequence of disconnected tools. An interactive workflow lowers that barrier: users can inspect candidate modes, revise frequencies and damping estimates, and restart the fit when the diagnostics suggest a poor initialization. This does not eliminate expertise, but it makes expertise more productive and the analysis easier to audit.

The two-stage architecture also offers a useful general lesson for scientific computing. Sometimes the right path to a structured model is not to impose every constraint from the start. First estimate what the data say in a more permissive representation; then use the uncertainty in that estimate to find the most plausible structured version. In MIMOS, this avoids repeatedly evaluating the full frequency-domain fit during the mode-shape factorization, while the information-weighted projection aims to preserve the statistical qualities of direct estimation locally.

The results suggest where that strategy is especially useful: large MIMO systems with many channels and closely spaced flexible modes. On AVIS, the method dealt with thousands of parameters and a large set of resonances. On the wafer stage, it removed roughly three-fifths of the independent parameters while preserving almost all of the fit achieved in Stage 1. These are useful demonstrations of scalability, although two case studies cannot establish performance across every class of machine.

There is a meaningful distinction between fit and truth. A high percentage fit says that a model reproduces the measured frequency responses under the paper’s chosen scoring and weighting. It does not by itself show that every estimated mode corresponds perfectly to a physical component, that the model will predict behavior outside the measured frequency range, or that it improves a control system in operation. The paper’s focus is identification and model construction; those downstream validations remain important.

Nor is simplification free. The AVIS fit decreased after the projection, and the choice between proportional and general damping changes the model’s complexity and flexibility. General damping markedly improved AVIS’s fit in this experiment, but its additional degrees of freedom may not be justified in every dataset. Users still need to select frequency ranges, weights, modes and a damping model that match their questions and data quality.

What’s Next

The next test is not simply whether MIMOS can fit more systems, but whether the resulting models help engineers make better decisions. That could mean designing controllers that remain stable around resonances, identifying shifts that signal wear or damage, or comparing a prototype’s measured dynamics with a design model. Each application needs its own validation: a model useful for control may need different frequency coverage and error weighting from one intended for diagnosis.

Further work could also examine sensitivity to noisy or incomplete FRFs, the reliability of automatic mode initialization, and how well estimated physical parameters transfer across operating conditions. The toolbox includes choices and diagnostics that help users manage these issues, but the paper does not claim they disappear. In particular, the reported fits depend on experimental measurements, chosen model structures and initialization; industrial deployment would require testing under the conditions where the models will actually be used.

Still, the achievement is tangible. MIMOS takes a difficult multivariable identification problem—one with coupled modes, many channels and thousands of possible parameters—and turns it into an open, inspectable workflow that can return smaller models without throwing away much measured behavior. If those models make precision machines easier to understand and control, the benefit may show up far from the equations: in equipment that moves more predictably, engineering work that can be reproduced, and future systems designed with their dynamics in view. (van der Hulst et al., 2026)

Comments (0)