A transformer that changes its own voltage to make EV charging easier
A solid-state transformer can shift internal voltages to make a wide range of EV battery outputs easier for its isolated converters to handle.
Six modules demonstrated unequal DC-link voltages and power exchange—turning “imbalance” into a control tool.
A solid-state transformer could make one of the hardest parts of high-power electric-vehicle charging a little less hard: instead of forcing every charger module to handle the entire span from a low-voltage battery to a high-voltage one, it can shift its own internal voltage to follow what the vehicle needs. In laboratory tests, that adjustment reduced current stress and improved the efficiency of the isolated converter. The finding is promising, but the paper does not provide a single headline percentage for the improvement, and its demonstrated system is a prototype rather than a commercial charging station.
That distinction matters. A charging port may need to serve vehicles with very different battery voltages, and the converter between the grid and the battery has to work efficiently across that range. This paper proposes using a capability already embedded in a modular solid-state transformer—the ability to exchange power among its internal modules—to make the converter’s job more manageable.
The Science
A conventional distribution transformer changes voltage through magnetic coupling at the grid frequency. A solid-state transformer (SST) instead converts power through semiconductor switches and high-frequency isolation. That arrangement can offer control over power flow and multiple output ports, useful for fast-charging sites, storage, and other direct-current loads. The tradeoff is more complicated power electronics.
The design studied here has a grid-connected cascaded H-bridge, or CHB, front end. It is built from a series of submodules, each with its own direct-current link and isolated DC–DC converter. Each converter feeds a load port. In the architecture’s single-isolation-stage form, the vehicle’s port connects directly to its isolated converter, avoiding an additional downstream conversion stage. Fewer conversion stages can mean fewer components and losses, but it also leaves that isolated converter responsible for a wide output-voltage range.
That range can be substantial. The paper notes that recent charger designs have targeted 200–1000 volts. If the isolated converter always receives the same input voltage, it must handle a very broad conversion ratio—the ratio between its input and output voltages. Such a wide operating range can complicate converter design and may increase current stress or make it harder to maintain efficient switching.
The authors’ idea is to vary the DC-link voltages feeding those isolated converters. Ordinarily, a controller tries to keep the voltages of the CHB submodules equal. Here, adjacent modules are deliberately allowed to operate at different voltages. That gives each isolated converter a different input voltage, which can be chosen to better suit its output requirement.
An embedded balancing circuit (BC) makes the unequal voltages possible. It is a four-switch buck–boost converter, a circuit able to transfer energy between two DC links whether one is at a higher or lower voltage. An inductor stores and releases energy as switches operate. The circuit does not add another full conversion stage to each output; instead, it provides a power-sharing route between neighboring modules. Figure 1 shows the system arrangement, while Figure 2 shows the balancing circuit and its connection between submodules.
The balancing circuit can transfer power only during particular switching intervals created by the CHB. The authors call these intervals windows. The circuit must also respect limits on modulation—the control signal that determines how the CHB synthesizes its AC waveform—and on peak and root-mean-square (RMS) current. RMS current is a measure of the heating effect of a changing current, while peak current captures the maximum instantaneous stress on components.
The analysis focuses on a pair of adjacent modules. Their combined DC-link voltage and their combined fundamental contribution to the grid-side waveform are held constant; only the allocation between them changes. If the first module’s voltage is divided by the second’s, the paper calls that ratio . The fraction of the pair’s input power assigned to the first module is . Changing changes the power imbalance the BC must move from one module to the other.
The researchers calculate how much power the BC can transfer across each switching cycle, accounting for current building up, residual current flowing through diode paths, and the changing availability of switching windows over the AC waveform. They then compare this capacity with the power required to maintain a selected voltage split. In a second analysis, they examine a single-phase-shift dual-active-bridge (DAB), a common isolated DC–DC converter, and compare fixed input voltage with an input that follows the output requirement.
The paper’s evidence comes from both models and hardware. A six-submodule SST prototype demonstrates unequal DC-link voltages and power exchange between modules. Separate DAB experiments test the converter-level effect. This is meaningful experimental validation of the operating principle, though not a full-scale field trial of an integrated charging station.
What They Found
The first result is that voltage imbalance need not mean uncontrolled imbalance. With modulation alone, the pair can support a limited range of unequal voltages, as long as each module’s modulation amplitude stays within its allowed range. Enabling the BC broadens the range: one module can take a different share of the pair’s input power, and the BC transfers the resulting difference to its neighbor.
The authors quantify the feasible region by requiring the needed balancing power not to exceed the transfer capability available under the current and modulation constraints. The boundary is therefore not a universal voltage ratio. It depends on the load-power ratio, how heavily the modules are loaded, the CHB switching windows, and the balancing inductor. This is a useful engineering result: it turns “can we make the module voltages unequal?” into a constrained design calculation.
For a reference operating point, the paper sets the nominal modulation amplitude to . Under that setup, the adopted normalized current ceilings for the balancing inductor are approximately 2.353 for peak current and 1.664 for RMS current, each expressed relative to the paper’s current base. These are analysis limits based on a normalized comparison with rated grid-current values, not universal hardware ratings.
The study then connects voltage flexibility to the DAB. When the DAB input follows the desired output voltage within the feasible range, the calculated peak current falls compared with operation at a fixed input voltage. The ideal zero-voltage-switching (ZVS) region also grows. ZVS means that a switch turns on when the voltage across it is near zero, reducing switching losses. The improvement in the ideal ZVS region is a theoretical comparison; real converters face parasitic effects and operating conditions that can narrow it.
Experiments support the central mechanism. The six-submodule prototype demonstrates that adjacent DC links can be held at unequal voltages while the balancing circuits exchange power. In the separate DAB experiment, voltage following reduces current stress and improves measured efficiency. The supplied paper text does not include numerical percentages for the efficiency gain or current reduction, so those benefits should be read as demonstrated directions, not as a quantified promise for every charger.
The practical message is not that one circuit suddenly solves the full wide-voltage charging problem. Rather, the SST can use its internal power-routing capability as a second control lever. If a vehicle battery’s voltage changes, a controller may adjust the voltage presented to the isolated converter instead of asking that converter alone to span the entire change.
The switching details are important because they define the cost of that flexibility. The BC’s current must be built up during a window and may continue through diode paths after active switching stops. A pair of modules with a desired voltage split may therefore be infeasible if the required balancing power exceeds what the windows permit, or if achieving it would exceed peak or RMS current limits. The paper’s contribution includes those limitations rather than treating the balancing circuit as an unlimited source of adjustment.
Why This Changes Things
The broader context is a shift from designing every power-conversion stage to tolerate the widest possible operating range toward coordinating stages so that each works in a more favorable region. In a multioutput charger, battery voltages and power demands vary across vehicles and over time. A fixed input to each isolated converter can force it to cover a wide gain range, which can make magnetics, semiconductors, control, and efficiency harder to optimize.
A variable input offers a different tradeoff. The front end and balancing circuits take on some coordination work, potentially letting the isolated converter operate with lower current stress and a wider soft-switching region. If that leads to smaller or more efficient isolated converters, it could matter at charging sites where many high-power ports operate together. The paper does not establish those system-level savings, but it identifies a path worth testing.
The architecture also makes internal modularity useful in a less conventional way. CHB submodules are usually treated as units that should share voltage evenly. The study shows that equal voltage is not always the best operating target: a controlled difference can improve the downstream conversion ratio, provided the modules can exchange the necessary power. The balancing circuit becomes not merely a remedy for imbalance but an active tool for assigning voltage where it has the most value.
This is especially relevant to single-isolation-stage systems. Removing a downstream converter can reduce conversion steps, yet it tightens requirements on the converter that remains. Variable DC-link operation may help recover some of the flexibility lost by eliminating that stage. The gain is not free: balancing hardware, controls, sensing, protection, and current headroom all matter. Nor does a better DAB operating point automatically guarantee better total-system efficiency; losses in the BC and CHB must be counted alongside any DAB improvement.
There is a further caveat around scale and integration. The prototype demonstrates six submodules and the DAB tests show the isolated-converter benefit, but those results do not by themselves establish operation under every combination of port loading, grid disturbance, thermal condition, or fault. A real station would need coordinated controls that respond to changing vehicle demand while maintaining grid-side waveform quality and respecting semiconductor and inductor limits. The study’s feasible-region model is a foundation for that work, not a substitute for it.
What’s Next
The next step is to connect the pair-level analysis to a complete multiport system. The paper’s local model isolates adjacent submodules and assumes the remaining units retain nominal settings. A charging site may have several ports changing power at once, so researchers will need to determine how to distribute voltage adjustments and balancing power across an entire string. That includes deciding which converter should receive a voltage change and how to prevent one heavily loaded pair from becoming the bottleneck.
A full system study should also compare total losses. The DAB experiments report improved efficiency with voltage following, but the balancing circuit consumes current and introduces conduction and switching losses. Whether the whole SST becomes more efficient will depend on where the power goes, how often voltage adjustment is needed, and the efficiency maps of every stage. The same accounting will determine whether the design can reduce component size or cost, rather than simply shifting stress from one component to another.
Control and reliability deserve equal attention. The circuit relies on windows determined by CHB modulation, and its transfer capability changes with the timing and duration of those windows. Practical control must handle transitions, residual currents, and rapidly changing output demands without exceeding current limits. Longer-duration tests, fault handling, thermal measurements, and operation across a broader range of loads would help show how robust the approach is outside carefully controlled experiments.
Still, the paper points toward a useful design principle for electrification: flexibility does not always have to come from making one converter handle everything. Sometimes a system can do better by adjusting the conditions under which that converter works. If future prototypes validate the total-system benefits, internal voltage balancing could help multioutput SSTs serve diverse EV batteries with less current stress and more favorable switching—one more way to make high-power charging infrastructure adaptable without adding another conversion stage.
Sign in to join the conversation.
Comments (0)
No comments yet. Be the first to share your thoughts.