A transformer without iron? This 2 kW converter swaps magnetics for capacitors

A transformer without iron? This 2 kW converter swaps magnetics for capacitors
2 KW Prototype rating
Capacitors AC bridge component
Magnetic Parts Transformer role replaced

A 2-kilowatt power converter has moved energy across an electrical isolation barrier without using a transformer in its high-frequency AC link. Instead, it connects two current-controlled inverter bridges through a network of capacitors. That demonstration does not yet show that capacitors can displace transformers across the power grid. It does show a plausible new route around one of power electronics’ stubborn bottlenecks: the magnetic hardware that struggles to keep pace as semiconductor switches get faster (Nowakowski et al., 2026).

The proposed device is called a Capacitive Bridge Transformer, or CBT. “Transformer” here describes its role—transferring power while keeping the two electrical sides isolated—not a traditional iron-and-copper component. Its promise is potentially important for solid-state transformers, the power-conversion systems that could help connect renewable generation, storage, electric vehicles and different voltage levels. The paper’s evidence is an analytical model checked against a laboratory prototype, not a grid-ready product or a demonstration of lower cost, higher efficiency, or longer service life.

The basic switch is conceptual but consequential. Conventional dual active bridge converters use two voltage-source inverters linked by a magnetic transformer. The CBT instead uses current-source inverters and a capacitive bridge. This changes the passive components and the way the converter must be controlled. Capacitors can avoid magnetic core losses and may be easier to scale to higher switching frequencies, but the full system still has to manage insulation, electrical stress, reactive power and losses in its switches and capacitors.

Fig. 9: The prototype Capacitive Bridge Transformer.
Fig. 9: The prototype Capacitive Bridge Transformer. Source: Patrick Nowakowski, Cameron Little

The Science

A dual active bridge, or DAB, is a converter that moves energy between two DC electrical systems through a pair of switching bridges. “Dual active” means both sides can switch actively; changing the timing between them controls the direction and amount of transferred power. A transformer in the middle normally provides galvanic isolation: the two sides exchange energy, but their conductors are not directly connected. Its turns ratio—the relationship between the number of coil turns on each side—also helps match different voltages.

The standard DAB uses voltage-source inverters (VSIs), which behave as controlled voltage sources, and an AC transformer. That arrangement is well established. But the transformer combines several difficult design jobs: its core and windings generate losses, its leakage and magnetizing inductances interact, and its copper and electrical-steel supply can be volatile. As wide-bandgap semiconductors improve, the passive transformer can become the component that limits how fast the whole converter can operate.

The CBT takes a different route. Current-source inverters (CSIs) supply controlled currents to an AC network whose isolation and coupling are provided by capacitors. In the paper’s three-phase design, capacitors connect the phases on each side in delta arrangements, with a separate capacitive bridge coupling the two sides. The AC portion contains no magnetic components. Capacitors do not need a magnetic core, and their values can be selected independently rather than being entangled in the design of a single transformer.

This is not simply a matter of replacing one box with another. A voltage-source inverter is not suited to driving a capacitive network directly in the way the CBT requires. The architecture therefore pairs capacitive coupling with current-source bridges. The researchers describe this as a form of electrical duality: where a conventional DAB is organized around voltage sources and inductive coupling, the CBT uses current sources and capacitive coupling. The analogy helps explain the circuit, but the architectures are not interchangeable without redesigning the control and component choices.

The paper first establishes power flow for an idealized single-phase version, then works through the more complicated three-phase switching pattern. In practical operation, the CSI currents are chopped rectangular waveforms rather than perfect sinusoids. The analysis uses symmetry to divide the switching cycle into repeating intervals, tracking how charge moves among the capacitors. It derives relationships for transferred DC power, apparent power within the converter, and an effective turns ratio—the voltage-conversion behavior the capacitive network provides.

A central control variable is the phase shift between the two inverter bridges. Moving one bridge’s switching pattern relative to the other changes the power transferred. Because the six-step three-phase waveforms line up differently at different phase shifts, the paper divides operation into three regions: from zero to one-sixth of a normalized cycle, one-sixth to one-third, and one-third to one-half. Those intervals are pieces of the analytical operating map, not measured performance thresholds.

Analytical phase-shift regions

The paper divides normalized phase shift into three successive operating intervals for its power-flow analysis.

Analytical phase-shift regions
LabelValue
Region 1 lower bound0 cycle fraction
Region 1 upper bound / Region 2 lower bound0.1667 cycle fraction
Region 2 upper bound / Region 3 lower bound0.3333 cycle fraction
Region 3 upper bound0.5 cycle fraction

What They Found

The headline demonstration is a 2 kW experimental prototype. The authors say steady-state and detailed time-domain measurements verified the analytical models. In other words, the equations were not left as a circuit-level thought experiment: measured operation was compared with predictions for power flow and voltage-transfer behavior. The supplied paper text identifies figures showing model-versus-measurement comparisons, efficiency, unity voltage gain, and a 1:2 voltage boost. It does not provide the plotted numerical values or full experimental conditions for those figures, so this digest does not infer efficiencies or errors from the captions alone.

The core analytical result is that phase shift governs power transfer in a manner analogous to a conventional DAB, even though the coupling element and source behavior have changed. The equations relate power to the phase shift, the DC currents, switching period and capacitor values. This matters because a converter architecture is useful only if designers can predict how its controls and components shape power flow. The paper also derives an effective turns ratio, allowing the capacitive system’s voltage-transfer behavior to be considered in converter design rather than treating isolation as its only function.

Fig. 12: Output Power predicted by analytical model vs measured on prototype, 3-ϕ Δ-connected capacitors.
Fig. 12: Output Power predicted by analytical model vs measured on prototype, 3-ϕ Δ-connected capacitors. Source: Patrick Nowakowski, Cameron Little

The three phase-shift regions matter because the circuit’s active capacitor connections change as the bridges’ switching patterns move relative to one another. The model therefore uses different expressions in different intervals. The authors’ approach is to map the switching states onto equivalent circuits, calculate capacitor currents and voltages, and then use those quantities to derive power. This analysis is technically detailed, but its practical point is simple: the network’s behavior can be expressed in a way that guides component sizing and operating choices.

The architecture also makes internal apparent power a design concern. Apparent power reflects the total electrical loading, including energy that oscillates within the converter rather than reaching the load as useful real power. That internal circulation can drive current and voltage stresses even when net transferred power is lower. The paper derives an apparent-power expression to help estimate semiconductor and capacitor requirements. This is important precisely because avoiding a transformer does not automatically avoid losses or component stress; the replacement circuit must be judged as a complete system.

Fig. 15: Analytical model prediction vs experimentally measured effective turns ratio.
Fig. 15: Analytical model prediction vs experimentally measured effective turns ratio. Source: Patrick Nowakowski, Cameron Little

The figure descriptions indicate that the researchers measured the prototype near unity voltage gain and at a 1:2 voltage boost, each at 2 kW, and examined efficiency across output power. They also compare the analytical prediction with measured effective turns ratio. These are meaningful tests of more than a single operating point: the prototype was used to examine power transfer and voltage conversion under different conditions. But without the underlying plotted data in the supplied text, it is not possible to report an efficiency percentage, a model error, or a comparative advantage over a magnetic DAB.

Prototype power demonstrated

The paper reports a 2 kW experimental prototype and describes operation at 2 kW in both unity-gain and 1:2 boost conditions.

Prototype power demonstrated
LabelValue
Prototype demonstration2 kW
Unity voltage gain operating point2 kW
1:2 voltage boost operating point2 kW

The study therefore demonstrates a design possibility, not a finished verdict. It reports a 2 kW prototype and analytical-model verification; it does not establish that the CBT is more efficient, cheaper, smaller, or more reliable than a conventional transformer-based converter. Those outcomes depend on operating frequency, voltage rating, capacitor construction, switching devices, cooling and insulation design. The distinction matters: a promising topology can remove a particular constraint while introducing new engineering trade-offs.

Why This Changes Things

Power converters are the translators of the electrification era. Solar panels and batteries produce and store electricity in forms that must be converted to match grids, motors and other equipment. Solid-state transformers could make those conversions more flexible and compact, but their performance depends on every stage—including the high-frequency DC-DC converter at their center. If a passive component cannot keep up with faster switches, improvements in semiconductor technology may not translate into better systems.

The CBT targets this mismatch by removing magnetic components from the AC coupling portion of the DAB. Capacitors can be attractive at higher frequencies because they do not incur magnetic core losses, and their values can be chosen separately. The paper also points to potential advantages in energy density, series resistance and supply-chain exposure. These are motivations for the research, not all demonstrated outcomes of the prototype. Whether the whole converter gains on those dimensions requires direct comparisons under equivalent power, voltage, isolation and thermal requirements.

There is historical context, too. Current-source DAB concepts predate the familiar voltage-source version, but earlier examples lacked galvanic isolation or used thyristors switching at line frequency. That left them bulky and poorly suited to modern high-power-density applications. The CBT revisits the current-source path with a capacitive isolation bridge and modern switching devices. The interesting development is not that capacitive power transfer is new; it is the attempt to make capacitive isolation the core coupling mechanism in a bidirectional, isolated DAB architecture.

If further work confirms the claimed system-level advantages, applications could include modular power conversion where isolation, voltage matching and high-frequency operation are valuable. That could mean future solid-state transformer stages or other DC-DC links. The paper does not show deployment in a utility network or a commercial product, however. A 2 kW laboratory prototype is an important proof of operation, but scaling it raises questions about insulation coordination, fault handling, component aging and thermal management.

The supply-chain argument deserves similar care. Capacitors avoid reliance on transformer steel and large copper windings in the AC link, but they are not material-free. A practical system still needs components that meet voltage, lifetime and safety requirements, as well as semiconductors and DC-side energy-storage inductors. Diversifying the component mix may be valuable, but the paper does not quantify an overall supply-chain or lifecycle benefit.

What’s Next

The next test is comparative engineering. Researchers will need to measure efficiency and power density against a conventional DAB at matched ratings, across the full operating range, rather than infer an advantage from the absence of a magnetic core. The prototype figures include efficiency curves, but the available text does not give their values. Publishing those measurements alongside clear test conditions would help readers judge whether reduced magnetic losses offset losses and stresses elsewhere in the CBT.

Scaling also demands evidence. The authors identify a 2 kW prototype, while real solid-state transformer applications can require different voltage classes and power levels. Larger systems would need careful assessment of capacitor voltage stress, insulation distance, switch losses, fault response and long-term reliability. A capacitive isolation barrier must maintain safety and performance over time, not just pass power during a laboratory demonstration.

Control and component design are equally open. The paper derives power and apparent-power relationships across phase-shift regions, creating tools for selecting operating points. A subsequent design can use those tools to reduce internal circulating power, manage device ratings and evaluate alternative capacitor values. The analysis also gives a basis for testing the architecture under regenerative power flow, where energy travels in the opposite direction.

The bigger promise is not that transformers are about to disappear. They remain exceptionally useful, mature components. It is that power electronics may have another way to build an isolated energy link—one that could be better suited to some high-frequency designs. The 2 kW CBT shows that the idea can work in hardware. The next studies must show when it works better, at what cost, and at what scale.