At 90% relative humidity, a new sensor developed in Hefei could still detect dimethyl sulfide in breath at just 10 parts per billion. That matters because breath is an easy sample to collect, but measuring one gas in it can be difficult: moisture and other gases may confuse the result.
Dimethyl sulfide is normally found in breath in small amounts. Levels above 30 parts per billion have been associated with liver conditions including cirrhosis and hypermethioninemia. A dependable way to measure the gas could support noninvasive screening, which does not require taking a tissue sample. The new device is still a research result, not a ready-to-use medical test, but it addresses some obstacles that have made breath measurements challenging.
The team brought together researchers from the Hefei Institutes of Physical Science of the Chinese Academy of Sciences, the Key Laboratory of Odor Pollution Control of the Ministry of Ecology and Environment, and Shenzhen Technology University. Their sensor uses a thin filtering layer made from copper oxide and aluminum oxide. The layer captures hydrogen sulfide, a gas also commonly present in breath, before it reaches the sensing material. Dimethyl sulfide can pass through, and the layer also reduces interference from moisture.
That selective filtering made a large difference in the device's ability to tell the two gases apart. The sensor's response ratio for dimethyl sulfide compared with hydrogen sulfide rose from 3.3 to 50.4 after the layer was added. It detected dimethyl sulfide down to 10 parts per billion even in air with 90% relative humidity, a level chosen to test the effect of very moist conditions.
The researchers also tested breath samples designed to simulate those of people with liver disease. In these complex samples, the sensor detected small changes in dimethyl sulfide concentrations. Such a test is important because a sensor must work amid the mix of gases and moisture found in breath, not just in a clean laboratory sample.
The findings, published in ACS Nano, describe a Pd–WO3 sensor with a CuO/Al2O3 filtering overlayer. The study's authors say the results point to potential for breath-based liver disease screening. The figures show improved selectivity and sensitivity under challenging conditions; they do not establish that the device can diagnose liver disease in patients or replace existing medical checks.
For now, the work offers a practical step toward making breath analysis more reliable: filter out a gas that gets in the way, while letting the target compound reach the sensor. Further development and testing would be needed before the technology could be used in clinics. But the ability to detect a liver-linked compound at low levels in humid, mixed-gas samples gives researchers a clearer path to explore simple breath tests.