← News
Medicine Breakthroughs Medicine Breakthroughs Health

A 2D model can miss half the indoor infection risk

A 2D model can miss half the indoor infection risk
3 Buildings tested
VIRIS-3D-L Model name
2D Surface 2D model domain
4 Times extra computation time
Up To 50% infection risk underestimation

A model that treats a room as a flat map can underestimate indoor infection risk by as much as 50%. In a care-home simulation, the difference was stark: one resident’s estimated risk by midday was 90% in the three-dimensional model and 60% in the older one. The gap matters because the numbers produced by infection models can shape decisions about ventilation, occupancy and how long people can safely share a space.

The new model, called VIRIS-3D-L, changes two assumptions about what happens to infectious aerosols indoors. It tracks their movement through the room’s full three-dimensional volume, rather than assuming the concentration is the same from floor to ceiling. And it removes aerosols when they reach surfaces, rather than subtracting them uniformly from the air everywhere. Across simulations of a courtroom, a care home and a supermarket, the older model consistently predicted less risk. The more detailed model, however, took about four times as long to run.

That trade-off is the central story: the extra realism can matter, but it costs computing time, and the paper does not establish that its predictions are clinically accurate in every real building. It tests the effect of changing model assumptions, not the effect of deploying a specific public-health intervention. Still, when a model informs safety decisions, underestimating risk is not a neutral error.

The Science

VIRIS—the Viral Infection Risk Indoor Simulator—combines building layouts, people’s movements and a model of airborne transmission. It is designed to estimate where infectious aerosols accumulate and how much a susceptible person might inhale while moving through an indoor space. The original framework is computationally efficient: it can simulate a day of activity for dozens of people in seconds on a standard laptop, according to the paper.

The new study, by Neha Bansal, Katerina Kaouri and Thomas E. Woolley of Cardiff University, extends that framework. Its title’s phrase “surface deposition” refers to aerosol particles settling onto walls, floors, ceilings, furniture and other surfaces. The authors compare the original VIRIS with their extension, VIRIS-3D-L, in three modeled single-storey settings: a courtroom, a small care home and a supermarket.

To understand the change, picture a room containing an invisible cloud of particles. The original VIRIS represents that cloud on a two-dimensional floor plan. It assumes that concentration is uniform across the room’s height, so the model does not distinguish the air around a person’s face from the air near the floor or ceiling. That is a simplifying assumption, not a claim that real air behaves this way.

VIRIS-3D-L instead calculates aerosol concentration across a three-dimensional room. In the simulations, people are represented as point sources or sinks at 1.8 metres, a chosen mouth-level height. The model can therefore resolve vertical differences in concentration and represent how objects with different heights affect the space. In principle, a full 3D domain also makes it possible to model connected floors in multi-storey buildings, though this study tests only single-storey spaces.

The second change concerns how particles leave the air. In the original model, surface deposition is treated as a first-order global removal process: aerosols are removed throughout the modeled air domain at a specified rate. In the new model, deposition is localized at the room’s boundaries through a Robin boundary condition. Put simply, the air loses particles when they reach a surface, rather than having deposition treated as if it were happening everywhere in the room at once.

The researchers solve a reaction–diffusion equation: a mathematical description of how a quantity spreads from higher to lower concentrations while also being added or removed. The model includes diffusion, viral deactivation, ventilation, aerosol emissions from infectious people and inhalation by all occupants. It does not include airflow-driven transport such as advection, which the authors say can be neglected in the poorly ventilated settings considered. That choice is important: this is not a general-purpose model of every indoor airflow pattern.

For a consistent comparison, the team generated 2D and 3D meshes at the same stated element size, used the same FEniCS numerical library for both frameworks, and approximated point sources with small Gaussian distributions. The simulations used SARS-CoV-2 parameters and assumed poor ventilation, with the air-conditioning unit broken down in all three buildings. The courtroom had one infectious person and nine susceptible people over a three-hour hearing. The care home had one infectious resident and five susceptible residents over a 13-hour day. In the supermarket, 240 customers entered over four hours, with every sixth customer treated as infectious.

The model estimates infection risk from a person’s cumulative inhalation of infectious aerosols over time. This approach builds on the Wells–Riley framework, a way of translating inhaled dose into a probability of infection. It produces modeled risks, not observed infection outcomes for every simulated person.

What They Found

Across all three settings, VIRIS estimated lower risk than VIRIS-3D-L. The abstract summarizes the underestimation as “up to 50%”; the detailed results show that the size of the gap depends on the building and individual. The two models generally showed similar broad patterns over time, but the 3D, locally depositing model predicted faster increases in risk and, in some cases, substantially higher values.

The courtroom is the simplest case: a hollow room without furniture, with ten people remaining stationary during a three-hour hearing. At the end of the simulation, the predicted risk for two susceptible people was 0.5 in VIRIS and 0.6 in VIRIS-3D-L. Across the nine susceptible people, the older model’s estimates were reported as 8% to 28% lower relative to the new model. The authors say the 3D model’s predictions better align with the outbreak record associated with the courtroom, in which four people tested positive a few days after the hearing. That comparison is suggestive, not a full validation: a small number of observed cases cannot by itself establish which model is generally more accurate.

Figure 2: Comparison of the temporal infection risk, for nine susceptible individuals (P2 to P10), in a courtroom (Figure 1), estimated using Eq. (6) for: a) VIRIS (global removal, 2D domain), and b) VIRIS-3D-L (local removal, 3D domain).
Figure 2: Comparison of the temporal infection risk, for nine susceptible individuals (P2 to P10), in a courtroom (Figure 1), estimated using Eq. (6) for: a) VIRIS (global removal, 2D domain), and b) VIRIS-3D-L (local removal, 3D domain). Source: Neha Bansal, Katerina Kaouri

The care home produced the largest reported individual differences. By the end of the day, VIRIS underestimated risk for two residents by 47% and 50% relative to VIRIS-3D-L. For other residents, estimated risk reached 100% in both models, leaving little room for a visible difference in the final probability. Yet the timing still mattered: one resident’s modeled risk was 0.9 by noon under VIRIS-3D-L and 0.6 under VIRIS. That resident shared a common room with the infectious person during the morning.

The supermarket offered a different test. Customers moved continuously through shelves and checkout areas, usually spending about 7.5 minutes inside. The researchers grouped customers by entry time and compared estimated infection risk at the exit. Median-risk underestimation in VIRIS ranged from 16% to 25% relative to VIRIS-3D-L in the later entry periods; the reported gap in the maximum bounds of the distributions ranged from 29% to 45%. The authors also report generally greater variation in risk under the 3D model. In a busy shop, then, a single average may conceal meaningful differences between customers’ routes and exposure histories.

Figure 6: Comparison of customers infection risk at the exit time from the supermarket (Figure 5), determined using Eq.(6) for: a) VIRIS (global removal, 2D domain), and b) VIRIS-3D-L (local removal, 3D domain). The horizontal axis shows four non-overlapping 30-minute entry intervals: 8:00–8:30am, 9:00–9:30am, 10:00–10:30am, and 11:00–11:30am. The horizontal bar in the middle of the box represents the median infection risk. The lower boundary is the 25th percentile (Q1), and the upper boundary is the 75th percentile (Q3) of infection risk for customers who entered during the corresponding entry-time interval. The height of the filled box is the interquartile range, IQR=Q3−Q1. The hollow circles outside the box are data points beyond Q1−1.5IQR and Q3+1.5IQR, where rare and extreme cases lie.
Figure 6: Comparison of customers infection risk at the exit time from the supermarket (Figure 5), determined using Eq.(6) for: a) VIRIS (global removal, 2D domain), and b) VIRIS-3D-L (local removal, 3D domain). The horizontal axis shows four non-overlapping 30-minute entry intervals: 8:00–8:30am, 9:00–9:30am, 10:00–10:30am, and 11:00–11:30am. The horizontal bar in the middle of the box represents the median infection risk. The lower boundary is the 25th percentile (Q1), and the upper boundary is the 75th percentile (Q3) of infection risk for customers who entered during the corresponding entry-time interval. The height of the filled box is the interquartile range, IQR=Q3−Q1. The hollow circles outside the box are data points beyond Q1−1.5IQR and Q3+1.5IQR, where rare and extreme cases lie. Source: Neha Bansal, Katerina Kaouri

The model’s greater detail came with a clear computational cost. VIRIS took 1.6 minutes for the courtroom, 8.6 minutes for the care home and 25.0 minutes for the supermarket. VIRIS-3D-L took 7.0, 23.5 and 129.3 minutes, respectively. The supermarket’s 3D run therefore took just over two hours, compared with 25 minutes for the 2D run.

Runtime rises when the room becomes 3D

Reported computation times for the two model versions in the three simulated buildings.

Runtime rises when the room becomes 3D
LabelValue
Courtroom — VIRIS1.6 minutes
Courtroom — VIRIS-3D-L7 minutes
Care home — VIRIS8.6 minutes
Care home — VIRIS-3D-L23.5 minutes
Supermarket — VIRIS25 minutes
Supermarket — VIRIS-3D-L129.3 minutes

Reported care-home risk gaps

Underestimation by VIRIS relative to VIRIS-3D-L for the two residents with the largest reported end-of-day differences.

Reported care-home risk gaps
LabelValue
Resident P447 %
Resident P650 %

The paper reports that the increase is about fourfold on average. The exact multiplier differs by case: the courtroom takes roughly four times as long, the care home under three times as long, and the supermarket just over five times as long. The larger supermarket increase reflects a more complex layout and many moving customers, as well as the greater computational demands of solving the equation in a volume rather than a floor plan.

Why This Changes Things

The practical significance is not that every indoor risk estimate should automatically be replaced with a more elaborate simulation. It is that a model’s simplifying assumptions can push estimates systematically in one direction. If a tool is used to set a safe exposure duration or decide whether a room needs more protection, consistently low estimates could create false reassurance.

The paper offers a physical explanation for the difference. In the 2D model, the concentration is averaged over room height. That can smooth away vertical gradients and produce a lower estimate at breathing height. The global deposition term also removes particles from the air throughout the domain, including the breathing zone, rather than only when they reach surfaces. The new formulation addresses both features. In these simulations, that combination led to higher concentrations where people inhale and higher predicted risks.

This matters most when the space has substantial vertical variation or complex movement. Shelves, furniture and different occupant heights can shape how aerosols disperse and where they settle. In a multi-storey building, the height dimension is not a decorative detail: it is necessary to represent how spaces on different floors connect. The authors argue that VIRIS-3D-L is particularly suited to settings with varied people and furniture heights, frequent 3D movement or multiple floors.

But complexity is not automatically accuracy. The study changes two assumptions at once—moving from 2D to 3D and replacing global deposition with local surface removal—so it does not isolate how much of the risk difference comes from each change. Nor does it compare its predictions against a broad set of measured aerosol concentrations or infection outcomes across the three buildings. The courtroom outbreak offers a point of comparison, but not enough evidence to establish general predictive performance.

The assumptions also narrow the model’s domain. Airflow-driven transport is neglected, while ventilation enters through a removal rate. Real indoor air can be shaped by mechanical systems, open doors, thermal plumes, people’s movement and room-specific turbulence. In some settings, those processes may matter as much as the dimensionality of the calculation. The study’s results should therefore be read as a comparison under specified conditions, not a universal correction factor for all indoor infection models.

There is also a subtle distinction between a higher estimated risk and a measured increase in disease transmission. The paper’s “transmission rate” refers to how quickly the simulated infection-risk curves rise. It does not report a new outbreak or show that a specific real-world intervention would prevent a certain number of cases. That distinction matters for decision-makers: the model signals where older assumptions may be optimistic, but it does not settle what policy should follow.

Even with those caveats, the work gives public-health planners a useful choice. For a simple single-storey room, the original VIRIS may be adequate when speed matters and the question does not depend on vertical detail. For a crowded, furnished or multi-level setting, the 3D model may justify its extra runtime. The decision is not between “simple and wrong” and “complex and right”; it is about matching the model to the question and being explicit about uncertainty.

What’s Next

The authors point toward validation as an essential next step. A stronger test would compare simulated concentration patterns with measured aerosol concentrations at different heights and locations, in buildings with known ventilation and surface conditions. That could reveal whether the model’s higher breathing-zone concentrations are closer to reality, and in which kinds of rooms the difference is largest.

Future work could also separate the effects of the two modifications. Running a 3D model with global removal, and a 2D model with a deposition boundary condition where mathematically appropriate, would help identify which assumption drives the largest change. Testing varied surface materials and deposition rates could make the boundary treatment more realistic; the present study assumes all surfaces share the same removal rate.

The people in this version are also simplified as point sources and sinks at one shared height. Real occupants differ in height, posture, activity and respiratory output. The authors note that the framework can accept custom agent heights, but this study fixes them at 1.8 metres for simplicity. More detailed agent representations could help answer questions about children, seated patients, workers bending over shelves or people sharing rooms for long periods.

Finally, the model should be tested in multi-storey buildings, where the third dimension is not merely a refinement but a defining part of the environment. The study establishes that a 3D, surface-localized formulation can change modeled risks substantially, and that the added detail costs computing time. It does not yet show which building types benefit most in practice or how well the predictions generalize. Those are precisely the questions that could turn a more realistic simulation into a dependable tool for safer indoor spaces.