A patch no bigger than a wearable sensor could one day help catch heart damage in patients who feel perfectly well after surgery. Researchers at McMaster University in Hamilton, Ontario, have developed a device that tracks cardiac troponin, a protein released when the heart is injured, without relying on repeated blood tests.

The need is substantial. About 300 million people around the world undergo surgery that does not involve the heart each year, and more are going home on the day of their operation. In the days afterward, some face myocardial injury after noncardiac surgery, known as MINS. About 20% of higher-risk patients experience it, and most cases have no obvious symptoms. Lead researcher Leyla Soleymani says about 90% of these injuries are silent. For patients already at home, a blood test can be hard to arrange.

The McMaster team’s patch uses microscopic polymer needles that reach just below the skin, without reaching nerves or blood vessels. They collect interstitial fluid, the liquid around the body’s cells, and pass it to a sensor that measures troponin continuously over several days. The needles are designed to sample fluid comfortably and without pain.

That kind of monitoring is harder than tracking sugar in the blood. Troponin is present at very low levels, and it is even more diluted in fluid beneath the skin. The researchers combined antibodies, which recognize proteins, with aptamers—short, engineered strands of DNA or RNA that bind to a chosen target—to turn the protein’s presence into a measurable signal. The sensor also needs to refresh itself so it can keep working over time.

The study, published in Science Advances, brought together researchers from several institutions. University of Waterloo researchers developed the microneedle technology. Mahla Poudineh, now an associate professor at NYU’s Tandon School of Engineering, said making the needles work with sensing electrodes was a key step. At McMaster, Bernardo Trigatti helped test the device in mouse models of heart disease. Such tests help researchers understand how the system might perform in living bodies, but they do not show that it is ready for routine patient care.

The patch could eventually give care teams a way to watch for heart injury during the risky days after an operation, including after a patient has gone home. Continuous readings might help identify people who need follow-up without asking them to return for repeated blood draws. The researchers have not yet demonstrated that the device can diagnose MINS in human patients, so clinical testing will be needed before its usefulness in post-surgery care is clear.

For now, the work marks a step toward monitoring a hard-to-measure protein through the skin. Soleymani says the aim was to watch for heart injury continuously without repeated blood draws. If future studies show the patch works reliably in people, a small wearable sensor could help bring attention to a problem that often gives patients no warning.